An internationally recognized testing institution, assisting enterprises in achieving technological advancement.
ZHONGXI Testing has obtained inspection qualification certifications from multiple countries and regions worldwide. We possess a senior testing team and advanced testing methods, providing independent, impartial, and professional third-party verification services for global carbon projects.
Certified by multiple international standards such as CNAS, VCS, and GS, with reports universally applicable worldwide.
Covering 140+ countries and regions, it supports on-site detection and remote verification in multiple languages.
Adopt standard experimental methods to ensure accurate and reliable data.
Before sending samples for evaluation, most engineers and quality managers have the same foundational question: Does this laboratory support the materials or chemicals under consideration? At our CNAS/CMA-accredited testing and inspection facility, we offer specialized guinea pig sensitization testing to address this critical query. This test method, predicated on international standards such as OECD guideline 404, is designed to assess the potential of a substance to induce allergic contact dermatitis (ACD) in humans. By employing the guinea pig model, we provide a scientifically robust assessment of skin sensitization potential, enabling clients to make informed decisions regarding product safety and regulatory compliance. This service is particularly relevant for chemicals and materials used in consumer products, pharmaceuticals, cosmetics, and industrial applications where skin exposure is a concern.
Our guinea pig sensitization testing capability covers a diverse range of chemical and material types, including but not limited to:
Materials are evaluated across various grades and concentrations, depending on their intended application. For instance, pharmaceuticals may be tested in sterile, controlled conditions, while industrial chemicals might be analyzed in their commercial formulation. The test is particularly relevant for substances intended for dermal contact or inhalation. Commonly referenced standards guiding this testing include OECD Guideline 404, ISO 10993-5, and EN 341. These frameworks ensure the test aligns with global regulatory requirements and provides consistent, scientifically valid results.
The guinea pig sensitization test evaluates the sensitizing potential of a test substance through a standardized protocol. Key test items and parameters include:
Below is a table summarizing typical parameters and graded limit requirements for the test:
| Parameter | Typical Value | Graded Limit |
|---|---|---|
| Induction dose (mg/cm²) | 0.1, 1.0, 10.0 | Test substance concentration must fall within the graded range |
| Challenge dose (mg/cm²) | 1.0, 10.0 | At least one dose must elicit a positive response in >50% of guinea pigs |
| Sensitization response score (max) | 0-4 (erythema, edema, papules) | Positive response: Mean score ≥ 1.0 at the challenge dose |
| Positive control response | - | Must achieve >50% positive response in control group |
The test results are categorized as negative, borderline, or positive based on the response rate and severity. A positive result indicates the test substance has sensitization potential, while a negative result suggests otherwise. Graded limits are determined based on historical data and international guidelines to ensure reproducibility and comparability across studies.
In assessing parallel-sample and batch-to-batch variation, our laboratory employs rigorous statistical methods to ensure data reliability. For parallel-sample variation, we calculate the relative deviation between duplicate or triplicate samples. Typically, the relative deviation for induction and challenge responses is maintained within ±15% to ensure consistency. This is achieved through standardized protocol adherence, including randomization of test animals and operators, and controlled environmental conditions.
Batch-to-batch variation is evaluated by comparing results from consecutive test submissions of the same material. The acceptance window for batch-to-batch consistency is defined as a mean response rate deviation of ≤20% between batches, with no single batch deviating by >30%. This ensures that variations in raw material sourcing or synthesis do not compromise the test's sensitivity or reliability. All variation data is reported in the final certificate, along with confidence intervals and statistical significance assessments. This approach provides clients with transparent, defensible data for decision-making.
For your testing requirements, please confirm your item list and sample quantity. We will revert with a formal quotation and expected schedule based on your submission details.
Beijing ZKGX Institute of Science and Technology , combining applied research with technological transformation. It has evolved into a comprehensive research institute characterized primarily by a "task-driven disciplines" approach. Approved by relevant authorities, it currently operates as a third-party analytical testing technical service provider. Its affiliated laboratory facilities hold certifications including CMA and CNAS, possess an Experimental Animal Use License, and have achieved triple certification for ISO9001 Quality Management System, ISO14001 Environmental Management System, and ISO45001 Occupational Health and Safety Management System.