Nose Patch Pollen Filtration Efficiency Testing Services

Nose Patch Pollen Filtration Efficiency Testing Services

An internationally recognized testing institution, assisting enterprises in achieving technological advancement.

Reasons for choosing our testing services

ZHONGXI Testing has obtained inspection qualification certifications from multiple countries and regions worldwide. We possess a senior testing team and advanced testing methods, providing independent, impartial, and professional third-party verification services for global carbon projects.

Internationally recognized authority

Internationally recognized authority

Certified by multiple international standards such as CNAS, VCS, and GS, with reports universally applicable worldwide.

Global service capability

Global service capability

Covering 140+ countries and regions, it supports on-site detection and remote verification in multiple languages.

Professional experimental methods

Professional experimental methods

Adopt standard experimental methods to ensure accurate and reliable data.

A well-defined testing scope is the first sign of a competent laboratory. In our capacity as a CNAS/CMA-accredited third-party testing and inspection laboratory, we specialize in evaluating the filtration efficiency of nose patches against pollen particles. This service is critical for manufacturers and quality managers in the medical and personal protective equipment sectors, ensuring that their products meet stringent performance requirements. Our testing capabilities are designed to provide objective, data-driven insights into the effectiveness of nose patch designs, materials, and manufacturing processes.

Testing Scope

Our nose patch pollen filtration efficiency testing covers a range of products, materials, and application scenarios. The applicable products include disposable and reusable nose patches used in healthcare, industrial, and consumer markets. Materials tested include non-woven fabrics, meltblown membranes, and other proprietary filter media. We evaluate various grades of nose patches, from basic single-layer designs to advanced multi-layer configurations with integrated active carbon or antimicrobial treatments. Application scenarios include surgical environments, dusty industrial settings, and everyday use for allergy sufferers.

Commonly referenced standards for this testing include ASTM F2100 (Medical Face Masks), ISO 22610 (Dust Masks), and EN 149 (Respiratory Protective Devices). These standards provide the frameworks for evaluating filtration efficiency, particle size distribution, and breathability. Our laboratory is equipped to perform testing according to these and other relevant international or regional standards, ensuring compliance with global regulatory requirements.

Testing Items and Parameters

The testing process involves multiple parameters to comprehensively assess the nose patch's performance. Key test items include particulate filtration efficiency, airflow resistance, and breathability. Each parameter is measured under controlled conditions to ensure consistency and reproducibility.

Typical parameters and graded limit requirements are outlined in the table below:

Parameter Typical Range Graded Limit
Particulate Filtration Efficiency (≥0.3 µm) 95% - 99% ≥95% (medical grade), ≥90% (industrial grade)
Flow Resistance (at 30 L/min) 5 - 20 cm H2O ≤30 cm H2O
Breathability (mm H2O/L/min) 50 - 150 ≥80
Differential Pressure (inward) 2 - 10 cm H2O ≤15 cm H2O

Additional parameters may include humidity resistance, chemical compatibility, and durability under repeated use. The graded limits are based on industry standards and client-specific requirements, with medical-grade products typically requiring stricter performance criteria than industrial or consumer-grade alternatives.

Data and Variation Analysis

Parallel-sample and batch-to-batch variation is rigorously assessed to ensure product consistency and reliability. For each test run, at least three parallel samples are evaluated to determine the average performance and relative deviation. Relative deviation is calculated as the standard deviation divided by the mean, expressed as a percentage. Typically, we accept a relative deviation of ≤5% for filtration efficiency and ≤10% for flow resistance parameters.

The laboratory maintains strict acceptance windows for batch-to-batch consistency. These windows are established based on historical performance data and are typically defined as ±10% for filtration efficiency and ±15% for flow resistance. Any batch falling outside these windows undergoes immediate re-testing to identify potential manufacturing variations. The results are reported with detailed variation analysis, including confidence intervals and statistical significance, to support quality control decision-making.

Data presentation includes graphical representations of performance trends, alongside tabular summaries of key parameters. Statistical methods such as ANOVA (Analysis of Variance) may be applied to assess significant differences between samples or batches, ensuring that the reported results are both precise and meaningful.

Confirm your required testing items and sample quantity first; we will revert with a formal quotation and expected schedule.

Submit detection request

Fill in the information to obtain a professional testing plan

About Us

Beijing ZKGX Institute of Science and Technology , combining applied research with technological transformation. It has evolved into a comprehensive research institute characterized primarily by a "task-driven disciplines" approach. Approved by relevant authorities, it currently operates as a third-party analytical testing technical service provider. Its affiliated laboratory facilities hold certifications including CMA and CNAS, possess an Experimental Animal Use License, and have achieved triple certification for ISO9001 Quality Management System, ISO14001 Environmental Management System, and ISO45001 Occupational Health and Safety Management System.